Twin Big Blue 2045PW5 & 2045-2kg KDF85/ORC

New Installation

  • Do not install in direct sunlight.
  • Mount the system a minimum of 100mm off the ground to allow the removal of filters.
  • Check flow direction which is marked on top of the system.
  • If on Mains Water supply it is recommended to have a PLV (pressure limiting valve) fitted before the system.
  • If you are using a pressure pump to supply the water, a PLV may still be required. 
  • After installing make sure to flush the new filters for 5 – 10 litres by opening the first tap after the filter system or use the Sump Flushing method. See flushing instructions below.

Flushing new filters – Twin System Sump Flushing Method

  • Turn off water supply.
  • Release pressure from system by either depressing Pressure Relief Button on head (if installed), or opening 1st tap after system.
  • Undo both filter sumps, remove and discard old filters then clean inside of sumps and lubricate o-rings.
  • Place new Carbon Filter into sump and install into the Sediment First Stage of your twin filter housing, leaving the second stage empty and without the sump attached.
  • Place a bucket (minimum 4L capacity) underneath second stage to catch flushed waste water.
  • Slowly turn on water supply and flush until bucket fills and water runs clear of fines – repeat if necessary.
  • Turn off water supply again.
  • Undo freshly flushed carbon filter and insert new sediment filter into first stage and re-insert carbon filter into second stage.
  • Hand tighten sumps only – do not use Sump Spanner to tighten, use for undoing only.
  • Slowly turn on water supply again – you may still have some air bubbles, this should disperse within a few hours or days.
  • Check system for leaks around sump seals and fittings.

You have finished flushing the new filters in your system. 

Cleaning and opening the filter system

  • Turn off the water supply to the system, release the water pressure in the pipes by opening the first tap after the filters and leave it turned on. 
  • Use the housing spanner to undo the sumps, turning from RIGHT to LEFT. 
  • Remove the dirty filters and using a bottle brush, clean housing sumps and head, then rinse with clean water.
  • Using a clean cloth or paper towel, wipe around the o-ring seal and where it seats. Before replacing the o-ring, use a small amount of food grade silicone grease to keep the o-ring supple and to help it seal (vegetable or cooking oil will do the same job – do not use petroleum based lubricants).

Only hand tighten the housing sumps – do not use the spanner – then wipe dry with a clean cloth.

Replacement Filters

The canister in stage II (carbon filter) of this system can be reused and refilled:

            Stage I             2045PW5                                 Pleated Washable 5 micron Sediment Filter

            Stage II             2045-2kgKDF85/ORC               Refillable Catalytic Carbon Media Canister Filter

                                                                                    Stage layers from base to top:

  • Bottom separator pad
  • 2kg KDF85
  • Separator pad
  • 1.6 kg ORC Catalytic Cabon media
  • Top separator pad

Wash sediment filter with hose every 2 – 3 months or whenever flow is restricted. 

Replace the carbon at 6 – 12 months as required.

WARNINGS

  • Do not install on line pressure above 125 psi.
  • Do not install in direct sunlight or next to sources of heat.
  • Protect from freezing.
  • Installation must comply with local plumbing codes.
  • Use of Parallel Thread fittings and/or Liquid Thread Sealant will VOID warranty
  • Activated carbon filters are not intended for use where water is microbiologically unsafe or with water of unknown quality.